Holtop Suspended AHU Air Handling Unit with Heat Recovery
Holtop Suspended AHU Air Handling Unit with Heat Recovery
Holtop is a factory providing Suspended AHU Air Handling Units with Heat Recovery. Our top-quality products are designed to improve air quality and save energy. Contact us today for a quote! #airhandlingunits #heatrecovery #factory #sustainability
Main features: • Equipped with supply fan and exhaust fan, brings in the fresh air and exhausts out stale indoor air as well. • Equipped with plate heat exchanger, recovers energy from outgoing indoor air, to save operating costs. • Thin height, easily installed in the ceiling space.Housing construction a. Double skin panel 25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high-density fireproof PU with a thermal coefficient below 0.0199W/m∙˚C b. High airtightness Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3% Supply fan and exhaust fan Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level. Heat exchangers
Total heat or sensible heat type available for different applications. The total heat exchanger is made of special fiber paper, featured by high moisture permeability, good airtightness, excellent tear resistance, and aging resistance. Suitable for high humidity difference between conditioned space and outdoors.
The sensible heat exchanger is made of thin aluminum foil, featured by high heat conductivity and long service life. Suitable for the high-temperature difference between indoors and outdoors.
Airflow damper (optional)
The edges of the lamina are with special plastic seals, which ensures low leakage.
Manual or motorized control is available for options.
Water cooling/heating coil
Copper pipe with double-side bent wave hydrophilic aluminum foil, higher heat exchange performance.
Air releaser and drainage plug are set in pipe connection box to ensure return path free from accumulated air, convenient for maintenance in winter.
Filter
Plate type(G2) coarse filter as standard configuration (Medium filter F5~F8 available as per request of the customer)
Draw-push installation, easy maintenance.
ELECTRICAL CONTROL
Standardly, we do not offer control boxes and related control components for AHUs but offer wiring terminals only. Besides, we offer the following control system as options. • Independent run/stop of supply fan and exhaust fan • Water switch control and temperature control • LCD thermostat controller • DDC (PLC) controller is optional
SUITABLE AIRFLOW
Model
Suitable airflow
HJK-010RQC~HJK-015RQC
1000m3/h~1500m3/h
HJK-020RQC~HJK-025RQC
2000m3/h~2500m3/h
HJK-030RQC~HJK-040RQC
3000m3/h~4000m3/h
HJK-050RQC~HJK-060RQC
5000m3/h~6000m3/h
HJK-080RQC~HJK-100RQC
8000m3/h~10000m3/h
PERFORMANCE PARAMETERS Parameter charts (fresh air condition)
Model
L*W*H (mm)
Ratedairflow(m3/h)
Supply fan
Exhaust fan
Coil
Heatrecoveryefficiency (%)
Filterclass
N.W.(Kg)
Inputpower(kw)
ESP(Pa)
Inputpower(kw)
ESP(Pa)
Rows
Coolingcap.(kw)
Heatingcap.(kw)
Waterinlet/outpipespec.
HJK-010RQC4DY1
2084*1120*550
1000
0.25
155
0.25
180
4
12.2
13.1
DN32
60
G2
240
HJK-015RQC4DY1
2084*1200*570
1500
0.32
155
0.25
180
4
18.4
19.8
DN32
60
G2
260
HJK-020RQC4DY1
2194*1280*570
2000
0.45
160
0.32
190
4
25.2
27
DN40
60
G2
280
HJK-025RQC4DY1
2244*1400*620
2500
0.55
160
0.55
190
4
30.4
33.1
DN40
60
G2
310
HJK-030RQC4DY1
2354*1400*630
3000
1
250
1
250
4
36.4
39.7
DN40
60
G2
360
HJK-040RQC4DY1
2404*1400*695
4000
1
290
1
330
4
14.9
46.4
DN50
60
G2
400
HJK-050RQC4DY1
2554*1530*705
5000
1.5
330
1.5
350
4
50.2
56.7
DN50
60
G2
440
HJK-060RQC4DY1
2634*1750*800
6000
2.2
400
1.5
400
2
66
68.3
DN65
60
G2
530
HJK-080RQC4DY1
2904*2000*900
8000
3
430
3
430
2
83.9
86.4
DN65
60
G2
690
HJK-100RQC4DY1
2904*2200*960
10000
4
500
4
500
2
108.5
110.4
DN65
60
G2
770
Working Conditions:• Cooling: Outdoor air DB35˚C, WD28˚C, cold water inlet/outlet temperature 7˚C/12˚C.• Heating: Outdoor air DB0˚C, hot water inlet/outlet temperature 60˚C/50˚C.